Honeywell
*41: enter receiver phone number *43: enter account number *47; enter 1 *48: enter 7, 7 *49: enter option 5...
Vista 128BP(32FB)
Enter Programming <installer code> + 800 *93 (Menu Mode Programming) Select ‘Device Programming’ Device ‘20’ Device Type ‘01’ Device Type...
DSC PowerSeries
Section 015: disable option ‘7’ Section 301: enter receiver phone number Section 310: enter account number Section 350: enter 03...
Keyswitch on DSC NEO
Section 015: Disable option ‘7’ Section 301: Enter Receiver number Section 350: Enable contact ID form Section 380: Enable option...
DSC PC5010/1555
**This panel may require CID Reporting codes be manually entered. (Section 320-351) **The panel CAN use a Virtual Keypad in...
GE Caddx
Enter Device 0 Location 0: enter receiver phone number Location 1: enter account number Location 2: enter 13
DSC NEO
Section 015: Disable option ‘7’ Section 301: Enter Receiver number Section 350: Enable contact ID form Section 380: Enable option...