**This panel may require CID Reporting codes be manually entered. (Section 320-351)

**The panel CAN use a Virtual Keypad in which you can Arm & Disarm using a User Code

  • Section 015: Disable option ‘7’(Turns on/off telephone line)
  • Section 301: Enter a Receiver number
  • Section 310: Enter an Account number
  • Section 360: Enter ’03’ (Enables Contact ID)
  • Section 365: Enable option ‘1’ (Enables Opening/Closing)
  • Section 380: Enable option ‘1’ (Enables Communications)
  • Section 381: Enable option ‘5’ (Enables Code Reporting)