To A BAT-LTE

  • Terminal 1(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 2(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 3(6-24v-POS AUX) should be wired to Pos aux on the panel
  • Terminal 4(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 5(Y IN) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 13(OC1) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parallel on Terminal 3 to Terminal 5 on the BAT CDMA

To A BAT-CDMA (green board)

  • Terminal 1(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 2(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 3(6-24v-POS AUX) should be wired to Pos aux on the panel
  • Terminal 4(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 5(Y IN) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 13(OC1) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parallel on Terminal 3 to Terminal 5 on the BAT CDMA

To A BAT-CDMA (black board)

  • Terminal 1(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 2(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 3(POS AUX) should be wired to Pos aux on the panel
  • Terminal 4(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 5(Y/TX) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 15(zone) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parallel from Terminal 3 to Terminal 5 on the BAT CDMA

To a CAT-CDMA-L (black board)

  • Terminal 1(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 2(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 3(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 4(POS AUX) should be wired to Pos aux on the panel
  • Terminal 5(PGM) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 15(ZN) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parallel from Terminal 3 to Terminal 5 on the CAT CDMA

To a CAT-CDMA (red board)

  • Terminal 1(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 2(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 3(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 4(POS AUX) should be wired to Pos aux on the panel
  • Terminal 5(PGM) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 8(ZN) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parallel from Terminal 4 to Terminal 5 on the CAT CDMA

To A BAT-CDMA-L

  • Terminal 1(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 2(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 3(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 4(POS AUX) should be wired to Pos aux on the panel
  • Terminal 5(PGM) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 15(ZN) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parallel from Terminal 3 to Terminal 5 on the BAT CDMA L

To a BAT-CDMA/WIFI/LTE

  • Terminal 1(TIP) should be wired to Tip on the alarm panel (used for communication)
  • Terminal 2(RING) should be wired to Ring on the alarm panel (used for communication)
  • Terminal 3(POS AUX) should be wired to Pos aux on the alarm panel
  • Terminal 4(NEG AUX) should be wired to Neg aux on the alarm panel
  • Terminal 5(Y IN) should be wired to the Yellow terminal on the alarm panel (used for interactive service)

·       Terminal 6(G IN) should be wired to the Green terminal on the alarm panel (used for interactive service)